WR J Sheathed Thermocouple

4 sku

WR J Sheathed Thermocouple

Technical parameters

1. Insulation: ceramic or ore quality insulation;
2. Structure type: single, double or several temperature sensing elements
3. Measuring range: -200~1800℃
4. Explosion-proof form: explosion-proof enclosure.

Executive standard

GB/T30429-2013

Supply capability

Brand : LEAGOO

Guarantee period : 12 months

Enquiry Now
WSSN Multi-angular Bimetal Seismic Thermometer

4 sku

WSSN Multi-angular Bimetal Seismic Thermometer

Technical parameters

1. Casing: 65, 80, 100, 150mm, optional;
2. Temperature sensing probe diameter: 6.35, 8, 10mm, optional;
3. Temperature sensing probe length: 50 mm the shortest, customized;
4. Indicator dial: aluminum, black characters on a white background.
5. Range: -50~600℃, customized.
6. Filling fluid: silicone oil (default), glycerin, fluorinated oil, or propylene glycol, optional.

Executive standard

JB/T8803-2015

Supply capability

Brand : LEAGOO

Guarantee period : 12 months

Enquiry Now
Ferrule flange-type electric contact bimetal thermometer

1 sku

Ferrule flange-type electric contact bimetal thermometer

Technical parameters

1. Electric contact: M upper and lower limit; N double upper limit; P double lower limit
2. Mount: Not fixed, movable external thread, movable external thread fixed thread, fixed flange, ferrule thread, ferrule flange
3. Structure: Axial type (straight), radial type (angle), 135° orientation (obtuse angle), universal type (adjustable angle)
4. Mount: Movable external thread, movable internal thread, fixed thread, fixed flange, ferrule thread, ferrule flange

Executive standard

QB

Supply capability

Brand : HENGHE

Guarantee period : 12 months

Enquiry Now
Fixed thread-type electric contact bimetal thermometer

1 sku

Fixed thread-type electric contact bimetal thermometer

Technical parameters

1. Electric contact: M upper and lower limit; N double upper limit; P double lower limit
2. Mount: Not fixed, movable external thread, movable external thread fixed thread, fixed flange, ferrule thread, ferrule flange
3. Structure: Axial type (straight), radial type (angle), 135° orientation (obtuse angle), universal type (adjustable angle)
4. Mount: Movable external thread, movable internal thread, fixed thread, fixed flange, ferrule thread, ferrule flange

Executive standard

QB

Supply capability

Brand : HENGHE

Guarantee period : 12 months

Enquiry Now
Fixed thread-type  heat distribution- type thermal resistor

1 sku

Fixed thread-type heat distribution- type thermal resistor

Technical parameters

1. RTD Qty.: single; double
2. Diameter of protecting tubes (mm): φ16, φ12
3. Type of junction box: splash-proof, water-proof
4. Operating terminal type: armored core, diameter variable/armored core
5. Mount: fixed thread, movable flange, fixed flange, activating pipe fitting, fixed thread tapering, straight pipe fitting, fixed-thread fitting, movable-thread fitting

Executive standard

QB

Supply capability

Brand : HENGHE

Guarantee period : 12 months

Enquiry Now
Movable-pipe joint-type heat distribution- type thermal resistor

1 sku

Movable-pipe joint-type heat distribution- type thermal resistor

Technical parameters

1. RTD Qty.: single; double
2. Diameter of protecting tubes (mm): φ16, φ12
3. Type of junction box: splash-proof, water-proof
4. Operating terminal type: armored core, diameter variable/armored core
5. Mount: fixed thread, movable flange, fixed flange, activating pipe fitting, fixed thread tapering, straight pipe fitting, fixed-thread fitting, movable-thread fitting

Executive standard

QB

Supply capability

Brand : HENGHE

Guarantee period : 12 months

Enquiry Now
Regular Temperature Transmitter

1 sku

Regular Temperature Transmitter

Technical parameters

1. Input: Thermocouple K-type, E-type, B-type, S-type, T-type, J-type, N-type RTD Pt100 Cu100 Cu50 (three-wire or four-wire system)
2. Output: Output 4~20ma DC signal within the range. Linear with the millivolt signal input by thermocouple; linear with the input resistance signal of the RTD. Or linear with temperature signal. As an isolation temperature transmitter, input and output phases are isolated with isolation voltage of 0.5KV, increasing resistance to common-mode interference, more suitable for use with computer networking.
3. Basic error: *±0.5% F・S
4. Transmission method: two-wire system
5. Display mode: (digital) LCD four-bit display, show a sign of e ... when open circuit of thermocouple occurs with output greater than 20mA
6. Working power: Min. voltage of transmitter working power is 12V, Max. voltage 35V, rated operating voltage 24V.
7. Load: Limit load resistance is calculated as follows:
RL (max)=50 (Vmin-12) (i.e. at 24V,
load resistance can be selected within 0~600Ω)
Rated load 250Ω.
8. Normal operating environment:
a) Ambient temperature: -25°C~80°C (Regular type)
-20°C~70°C (Digital display type)
b) Relative humidity: 5%~95%
c) Mechanical vibration: f≤50hz, amplitude <0.15mm
d) In ambient air, there is no corrosive medium for chromium, nickel coating, non-ferrous metals
and other alloys.
9. Impact of ambient temperature: ≤0.05/1°C
Note: "*" Contracted products with a tolerance error of ±0.2% can be provided if specially requested by customers.
10. Mount: regular type, dedicated type, wall mounted type and guide rail type

Executive standard

QB

Supply capability

Brand : HENGHE

Guarantee period : 12 months

Enquiry Now
Assembly thermocouple

1 sku

Assembly thermocouple

Technical parameters

1. Measurement range (°C): 0 ~ 1800;
2. Types: B, S, K, E, T, J, N;
3. Conductor materials: copper - copper nickel, iron - copper nickel, nickel chromium - copper nickel.

Executive standard

QB

Supply capability

Brand : HENGHE

Guarantee period : 12 months

Enquiry Now
SKW Digital Display Temperature Controller for Non-standard Heating Sleeve Configuration

3 sku

SKW Digital Display Temperature Controller for Non-standard Heating Sleeve Configuration

Technical parameters

1. Working voltage: ~220V 50HZ;
2. Range of temperature control: room temperature~400℃;
3. Display temperature: ±1℃;
4. Working hours: continuous use;
5. Specifications: 1000W, 2000W, 3000W.

Executive standard

Company standard

Supply capability

Brand : JINGJIA

Guarantee period : 12 months from the date of delivery

Enquiry Now
Bimetal Thermometer with Thermocouple (Thermal Resistance) Temperature Transmitter

1 sku

Bimetal Thermometer with Thermocouple (Thermal Resistance) Temperature Transmitter

Technical parameters

1. Level of protection: IP55;
2. Measuring range (℃): -80~500;
3. Accuracy class: 1.5;
4. Material of protective tube: 1Cr18Ni9Ti, 304, 316;
5. Insertion length (mm): 150-1000.

Executive standard

Enterprise standard

Supply capability

Brand : HENGHE

Guarantee period : 12 months after the ex-warehouse date

Enquiry Now