YWZ-200T Liquid Level and Temperature Indicator

1 sku

YWZ-200T Liquid Level and Temperature Indicator

Technical parameters

1. Corollary equipment: hydraulic station TDHPU280/16-8B-M

Executive standard

Company standard Q/TDJ01-2005

Supply capability

Brand : TENGDA

Guarantee period : 6 months from the date of delivery

Enquiry Now
WZP Series Temperature Transmitter

1 sku

WZP Series Temperature Transmitter

Technical parameters

1. Measuring range: -200~1800℃;
2. Conventional precision:±0.25%FS;
3. Power supply voltage: 13~30VDC;
4. Load resistance: 0~850Ω;
5. Output signal: 4~20mA;
6. Display mode: liquid crystal display;
7. Anti-explosion grade: dⅡBT4;
8. Protection grade: IP65.

Executive standard

Supply capability

Brand : YAHU

Guarantee period : no warranty

Enquiry Now
WZ Sheathed Copper Thermistor

10 sku

WZ Sheathed Copper Thermistor

Technical parameters

1. Insulation: ore quality insulation;
2. Structure type: single, double branch;
3. Measuring range: -200~800℃
4. Explosion-proof form: explosion-proof enclosure.

Executive standard

JB/T10500-2005

Supply capability

Brand : LEAGOO

Guarantee period : 12 months

Enquiry Now
YWZ-200T Liquid Indicator

1 sku

YWZ-200T Liquid Indicator

Technical parameters

1. Equipment: YZBF-120LD hydraulic station;
2. Part No.: YWZ-200T

Executive standard

Q/320623AD05

Supply capability

Brand : RUSHI

Guarantee period : 6 months from the date of delivery

Enquiry Now
WSS Multi-angular Bimetal Thermometer

4 sku

WSS Multi-angular Bimetal Thermometer

Technical parameters

1. Casing: 65, 80, 100, 150mm, optional;
2. Temperature sensing probe diameter: 6.35, 8, 10mm, optional;
3. Temperature sensing probe length: 50 mm the shortest, customized;
4. Indicator dial: aluminum, black characters on a white background.
5. Range: - 50 ~ 600℃, can be customized.

Executive standard

JB/T8803-2015

Supply capability

Brand : LEAGOO

Guarantee period : 12 months

Enquiry Now
WSS Axial Bimetal Thermometer

4 sku

WSS Axial Bimetal Thermometer

Technical parameters

1. Casing: 65, 80, 100, 150mm, optional;
2. Temperature sensing probe diameter: 6.35, 8, 10mm, optional;
3. Temperature sensing probe length: 50 mm the shortest, customized;
4. Indicator dial: aluminum, black characters on a white background.
5. Range: - 50 ~ 600℃, can be customized.

Executive standard

JB/T8803-2015

Supply capability

Brand : LEAGOO

Guarantee period : 12 months

Enquiry Now
Special Temperature Transmitter

1 sku

Special Temperature Transmitter

Technical parameters

1. Input: Thermocouple K-type, E-type, B-type, S-type, T-type, J-type, N-type RTD Pt100 Cu100 Cu50 (three-wire or four-wire system)
2. Output: Output 4~20ma DC signal within the range. Linear with the millivolt signal input by thermocouple; linear with the input resistance signal of the RTD. Or linear with temperature signal. As an isolation temperature transmitter, input and output phases are isolated with isolation voltage of 0.5KV, increasing resistance to common-mode interference, more suitable for use with computer networking.
3. Basic error: *±0.5% F・S
4. Transmission method: two-wire system
5. Display mode: (digital) LCD four-bit display, show a sign of e ... when open circuit of thermocouple occurs with output greater than 20mA
6. Working power: Min. voltage of transmitter working power is 12V, Max. voltage 35V, rated operating voltage 24V.
7. Load: Limit load resistance is calculated as follows:
RL (max)=50 (Vmin-12) (i.e. at 24V,
load resistance can be selected within 0~600Ω)
Rated load 250Ω.
8. Normal operating environment:
a) Ambient temperature: -25°C~80°C (Regular type)
-20°C~70°C (Digital display type)
b) Relative humidity: 5%~95%
c) Mechanical vibration: f≤50hz, amplitude <0.15mm
d) In ambient air, there is no corrosive medium for chromium, nickel coating, non-ferrous metals
and other alloys.
9. Impact of ambient temperature: ≤0.05/1°C
Note: "*" Contracted products with a tolerance error of ±0.2% can be provided if specially requested by customers.
10. Mount: regular type, dedicated type, wall mounted type and guide rail type

Executive standard

QB

Supply capability

Brand : HENGHE

Guarantee period : 12 months

Enquiry Now
WR T Sheathed Thermocouple

4 sku

WR T Sheathed Thermocouple

Technical parameters

1. Insulation: ceramic or ore quality insulation;
2. Structure type: single, double or several temperature sensing elements
3. Measuring range: -200~1800℃
4. Explosion-proof form: explosion-proof enclosure.

Executive standard

GB/T30429-2013

Supply capability

Brand : LEAGOO

Guarantee period : 12 months

Enquiry Now
WSSN Radial Bimetal Seismic Thermometer

4 sku

WSSN Radial Bimetal Seismic Thermometer

Technical parameters

1. Casing: 65, 80, 100, 150mm, optional;
2. Temperature sensing probe diameter: 6.35, 8, 10mm, optional;
3. Temperature sensing probe length: 50 mm the shortest, customized;
4. Indicator dial: aluminum, black characters on a white background.
5. Range: -50~600℃, customized.
6. Filling fluid: silicone oil (default), glycerin, fluorinated oil, or propylene glycol, optional.

Executive standard

JB/T8803-2015

Supply capability

Brand : LEAGOO

Guarantee period : 12 months

Enquiry Now
Regular Temperature Transmitter

1 sku

Regular Temperature Transmitter

Technical parameters

1. Input: Thermocouple K-type, E-type, B-type, S-type, T-type, J-type, N-type RTD Pt100 Cu100 Cu50 (three-wire or four-wire system)
2. Output: Output 4~20ma DC signal within the range. Linear with the millivolt signal input by thermocouple; linear with the input resistance signal of the RTD. Or linear with temperature signal. As an isolation temperature transmitter, input and output phases are isolated with isolation voltage of 0.5KV, increasing resistance to common-mode interference, more suitable for use with computer networking.
3. Basic error: *±0.5% F・S
4. Transmission method: two-wire system
5. Display mode: (digital) LCD four-bit display, show a sign of e ... when open circuit of thermocouple occurs with output greater than 20mA
6. Working power: Min. voltage of transmitter working power is 12V, Max. voltage 35V, rated operating voltage 24V.
7. Load: Limit load resistance is calculated as follows:
RL (max)=50 (Vmin-12) (i.e. at 24V,
load resistance can be selected within 0~600Ω)
Rated load 250Ω.
8. Normal operating environment:
a) Ambient temperature: -25°C~80°C (Regular type)
-20°C~70°C (Digital display type)
b) Relative humidity: 5%~95%
c) Mechanical vibration: f≤50hz, amplitude <0.15mm
d) In ambient air, there is no corrosive medium for chromium, nickel coating, non-ferrous metals
and other alloys.
9. Impact of ambient temperature: ≤0.05/1°C
Note: "*" Contracted products with a tolerance error of ±0.2% can be provided if specially requested by customers.
10. Mount: regular type, dedicated type, wall mounted type and guide rail type

Executive standard

QB

Supply capability

Brand : HENGHE

Guarantee period : 12 months

Enquiry Now