Heatless type Desiccant Air Dryer

1 sku

Heatless type Desiccant Air Dryer

Technical parameters

1. Max. inlet air temperature:60℃.
2. Pressure range (Mpa): 0.5-1.0.
3. Pressure dew point (℃): -40 (inquire for other options).
4. Inlet air oil content: ≤0.1PPm.
5. Regeneration air consumption: ≤14%.
6. Control mode: Microcomputer automatic control/PLC control.
7. Power supply: AC 220V/50HZ.
8. Cycle: T=10(min).
9. Design working condition: inlet temperature: 38℃, ambient temperature: 38℃, working pressure:0.7MPa, pressure loss: ≤design prssurex3%.

Executive standard

Supply capability

Brand : SHANLI

Guarantee period : 12 Months

Enquiry Now
Lubricating Oil Station

2 sku

Lubricating Oil Station

Technical parameters

1. Type of lubricating-oil station: XYZ10L-XYZ4000L;
2. Nominal pressure (MPa) 0.63;
3. Medium viscosity value (cSt): 22-460;
4. Filter fineness (mm) 0.08-0.25;
5. Temperature of water-inlet of the cooler (℃): ≤30;
6. Pressure of water-inlet cooler (MPa): ≤0.4;
7. Temperature of oil-inlet of the cooler (℃): 50;
8. Oil temperature drop of cooler (℃): ≥8;
9. Cooling water consumption (m³/h): 0.6-400;
10. Motor power (KW): 0.75-120;
11. Oil tank capacity (m³): 0.25-120;
12. Heat exchange area (m²): 1.3-400;
14. Filtration area(m): 0.05-15;
15. Weight (KG): 320-60000;

Executive standard

JB/ZQ4586-97

Supply capability

Brand : HUARUN

Guarantee period : 12 Months

Enquiry Now
Filter

6 sku

Filter

Technical parameters

1. Filter media: Lubricant; 2. Filtration accuracy: 10 ~ 15μm; 3. Maximum working pressure: 0.2bar; 4. Can be customized according to the customer's needs.

Executive standard

HB 6779-1993

Supply capability

Brand : TIANCHENG

Guarantee period : no warranty

Enquiry Now
ADF dry air generator

5 sku

ADF dry air generator

Technical parameters

1. Air supply (m³/H): 60-300;
2. Total power (kW): 8.5-58;
3. Working power: 380V/50HZ;
4. Work mode: twin-tower automatic alternative continuous;
5. Adsorbent material: activated alumina;
6. Regeneration mode: heatless;
7. Working pressure (MPa): 0.5~0.7;
9. Dew point (℃) : - 50~70;
10. Exhaust pressure (MPa): -0.1~0.3.

Executive standard

Company standard

Supply capability

Brand : XIBAO

Guarantee period : 12 months from the date of delivery

Enquiry Now
Room Temperature Water-cooled Refrigerated Air Dryer

1 sku

Room Temperature Water-cooled Refrigerated Air Dryer

Technical parameters

1. Max. inlet air temperature: 60℃ for room temperature type/80℃ for high temperature type.
2. Ambient temperature range (℃): 5 to 50.
3. Pressure range (Mpa): 0.6-1.6 (plate type/plate-fin type), 0.6-1.0 (tube-shell type).
4. Pressure dew point (℃): 2-10.
5. Cooling method: water-cooled (industrial circulating cooling water).
6. Cooling water pressure range(Mpa): 0.2-0.4.
7. Max. inlet cooling water temperature(℃): 38.
8. Power supply: AC 380V/220V/50HZ for 0.5-8Nm³/min.
9. Refrigerating agent: R22(optional:R407C/R134a).
10. Inlet cooling water temperature (℃): ≤38.
11. Design working condition: Inlet temperature: 38℃/80℃, ambient temperature: 38℃, working pressure: 0.7MPa and pressure loss:≤ design pressurex3%.

Executive standard

DIN ISO7183

Supply capability

Brand : SHANLI

Guarantee period : 12 Months

Enquiry Now
API10D Double Bow Spring Centralizer

2 sku

API10D Double Bow Spring Centralizer

Technical parameters

1.Applicable Casing Size; 5 1/2",9 5/8";
2.Applicable Size of the Hole; 8 1/2", 12 1/4";
3.MAX O.D.;230,335mm;
4.Match API 10D Standard or not; Yes.

Executive standard

API Spec 10D-2002

Supply capability

Brand : SHANGSHAN

Guarantee period : NA

Enquiry Now
ADF-300 Dry Air Generator

1 sku

ADF-300 Dry Air Generator

Technical parameters

1. Air volume (m³/H): 60-300;
2. Total power (KW): 8.5-58.
3. Working power: 380V/50HZ;
4. Work mode: twin towers automatic alternative and continual work;
5. Adsorbent material: activated alumina;
6. Regeneration mode: heatless regeneration;
7. Work pressure (Mpa): 0.5~0.7;
8. Vent pipe diameter (mm): 25-50;
9. Dew point (℃) : - 50~70;
10. Exhaust pressure (Mpa): -0.1~0.3.

Executive standard

Company standard

Supply capability

Brand : XIBAO

Guarantee period : 12 months from the date of delivery

Enquiry Now
0-70MPa oil cylinder

8 sku

0-70MPa oil cylinder

Technical parameters

1. Bore diameter: 20-800mm;
2. Rod diameter: 12-600mm;
3. Stroke: 0-6000mm(Best production: 0-3000mm);
4. Working Pressure: 0-70MPa.

Executive standard

GB/T15622-2005

Supply capability

Brand : HAKV

Guarantee period : no warranty

Enquiry Now
Refrigerate Air Dryer

4 sku

Refrigerate Air Dryer

Technical parameters

1. Gas displacement: 3m³/min, 6.6m³/min, 10.8m³/min, 11.3m³/min.
2. Environmental temperature: 38℃.
3. Power: 0.82kW, 1.13kW, 1.62kW, 2.71kW.
4. Power voltage: 220V, 380V, 230V.
5. Hz: 50HZ, 60HZ. 6. Joint pipe bore: 3/4, 1 1/2, 2", 2"NPT.

Executive standard

JB/T 20032-2012

Supply capability

Brand : SULLAIR

Guarantee period : 12 Months

Enquiry Now
QBWS-JZ Sophisticated Non-negative Pressure Water Supply Equipment

1 sku

QBWS-JZ Sophisticated Non-negative Pressure Water Supply Equipment

Technical parameters

1. Capacity range: 0-1000 m³/h
2. Pressure range: 0-2.5 MPa
3. Matched power: ≤132 kW
4. Pressure adjusting precision: ≤0.01 MPa
5. Ambient temperature: 0~40℃
6. Relative humidity: <90%(electronically controlled system)
7. Three-phase power supply, 380V (±10%), 50Hz±2Hz

Executive standard

GB/T 5656-2018

Supply capability

Brand : SSC

Guarantee period : One year from the date of delivery

Enquiry Now