Product characteristics

material
color
toecap
upper material
reflector tape
shell material
size
type
flow (l/s)
leather thickness (rubber outsole) (mm)
model
outlet pressure (mpa)
technology
manner of wearing
operating voltage
hat shell material
helmet lining style
sound level (db)
lens material
pc
toe cap
XBD12.0-G Vertical Fire Pump

4 sku

XBD12.0-G Vertical Fire Pump

Technical parameters

1. Outlet pressure: 1.03-1.25Mpa;
2. Flow: 21-45L/S;
3. Speed: 2950r/min;

Executive standard

GB6245-2006

Supply capability

Brand : JIALI TECHNOLOGY

Guarantee period : 1 year from the date of delivery

Enquiry Now
Linear heat fire detector

5 sku

Linear heat fire detector

Technical parameters

1. Operating voltage: DC24V±20%;
2. With constant temperature alarm function, and action temperature has two levels namely 85℃ and 105℃;
3、70℃ ≤ action temperature 85℃<100℃, detector response time is 22s, with deviation.

Executive standard

GB16280-2014 Linear Heat Fire Detector

Supply capability

Brand : Sureland

Guarantee period : 18 months since signing of the contract and 12 months since arrival and acceptance on site, while the priority is given to the first satisfaction of time.

Enquiry Now
Rain-pouring alarm valve

5 sku

Rain-pouring alarm valve

Technical parameters

1. Hydraulic friction resistance: 0.07Mpa;
2. Rated working pressure: 2.5Mpa;
3. Applicable for environment temperature above 0℃;
4. The material is stainless steel.

Executive standard

National standard GB9113.1

Supply capability

Brand : Sureland

Guarantee period : 18 months since signing of the contract and 12 months since arrival and acceptance on site, while the priority is given to the first satisfaction of time.

Enquiry Now
GT-1000 series point-type gas detector

1 sku

GT-1000 series point-type gas detector

Technical parameters

1. Applicable gases: Combustible gas, toxic gas, oxygen.
2. Test principle: Catalytic combustion type and electrochemical type.
3. Test way: Natural diffusion.
4. Working voltage: DC24V±6V.
5. Power consumption: ≤1.5W.
6. Response time: T90<30s (combustible gas); T90<60s (toxic gas).
7. Operation way: Infrared remote control.
8. Environmental conditions: Temperature: -40℃~70℃ (combustible gas); -20℃~50℃ (toxic gas). Humidity: ≤95%RH no condensation.
9. Status indication: Yellow LED indicates fault, red indicates concentration alarm and green indicates normal working.
10. Applicable cable: ≥RVVP3×1.5mm2, the outside diameter of cable is required as 6mm~9mm.
11. Output signal: 4~20mA, 2-circuit relay output.

Executive standard

GB-15322 1-2003 GB-12358 - 2006

Supply capability

Brand : Hanwei

Guarantee period : 12 months after leaving factory

Enquiry Now
Protable single gas detector

1 sku

Protable single gas detector

Technical parameters

1. Detection of gases: oxygen (0-30%).
2. Measurement method: electrochemistry.
3. Sampling method: spread type.
4. Display: digital LCD.
5. Voice alarm: 90 decibels.
6. Visual alarm: red LED.
7. Vibration alarm: vibration.
8. Battery: CR2 battery.
9. The operating temperature and humidity: - 20 ℃ to + 50 ℃, 10% ~ 95% RH.
10. Explosion-proof: EEx ia IIC T4 / IP67;
11. Shell: rubber PC shell.
12. Standard accessories: tape clamp, label cover.
13. Optional accessories: sampling pump.
14. Dimensions: 54mm (W) x91mm (H) x32mm (D)
15. Weight: 120 grams (including battery).

Executive standard

Supply capability

Brand : KANGSHIELD

Guarantee period : Storage instructions: 1. After using the instrument, make sure that the instrument has enough power, or put the amount of power in the underpressure and fill it up. Do not store the instrument when the battery is exhausted, so as not to damage the battery. 2. Keep the equipment in plastic bags or special boxes to keep the environment clean, dry and ventilated, and avoid dust accumulation or dampness. 3. Store the environment 0-40 degrees, away from high temperature and direct sunlight, so as not to damage the instrument or reduce the sensitivity. 4. Should be stored in the environment without corrosive gas, hydrogen sulfide and silicon vapor, avoiding instrument corrosion or poisoning. Instructions: 1. Pay attention to regular calibration and testing. 2. Note the detection interference between various sensors. 3. Pay attention to the life of various sensors. 4. Pay attention to the measuring range of the instrument. Guarantee period: 1 years.

Enquiry Now
Fire Pump Set

1 sku

Fire Pump Set

Technical parameters

1. Dimension: 3,800 x 2,680 x 2,250 mm;
2. Skid size: 3,800 x 2,680 x 388 mm;
3. Water tank volume: 1 m³;
4. Pump flow: 35 L/s;
5. Pump head: 70-120 m.

Executive standard

1. GB7956.1 Fire Engine Part I: General Technical Conditions; 2. GB20031-2005 General Conditions of Foam, Fire Extinguishing Systems, and Components; 3. GB/T 700 Carbon Structural Steel; 4. JB/T 4735 Steel Welding Pressure Vessel; 5. HG/T 20592-20635-2009 Steel Pipe Flanges, Gaskets, and Fasteners; 6. Q/SYBOMCO J075 Steel Structure Welding Code; 7. Q/SYBOMCO J078-2010 General Specification for Paint Painting; 8. NFPA 16-2007 Foam Sprinkler and Foam Sprinkler System Installation Standards.

Supply capability

Brand : YINHE

Guarantee period : 12 months from the date of delivery

Enquiry Now
8t foam & water-tanker fire truck

1 sku

8t foam & water-tanker fire truck

Technical parameters

1. Emission standard: GIV and GV (optional);
2. Model of chassis: Benz Actros2641;
3. Boundary dimension: 9,090x2,500x3,720mm;
4. Power: 300kW;
5. Jet range of fire monitor: 75m;
6. Flow of fire monitor: 80L/s.

Executive standard

GB 7956.1-2014

Supply capability

Brand : YINHE

Guarantee period : Within 12 months upon the delivery date

Enquiry Now
Saudi Aramco ZJ10DBS drill fire station

1 sku

Saudi Aramco ZJ10DBS drill fire station

Technical parameters

1. Boundary dimension: 6,800x3,000x2,674mm;
2. Skid dimension: 6,800x3,000x229mm;
3. Water tank volume: 12.7m³;
4. Foam tank volume : 2.3m³;
5. Flow of water pump: 35L/s;
6. Water pump lift: 70-120m.

Executive standard

1. Fire Truck Part 1: General Technical Conditions (GB7956.1); 2. General Specification for Foam Extinguishing System and Components (GB20031-2005); 3. Carbon Structural Steel (GB/T 700); 4. Steel Welded Atmospheric Pressure Vessels (JB/T 4735); 5. Steel Pipe Flanges, Gaskets and Bolting (HG/T 20592-20635-2009); 6. Steel Structure Welding Specifications (Q/SYBOMCO J075); 7. General Specifications for Paint Coating (Q/SYBOMCO J078-2010); 8. Code for Installation of Foam Sprinkler and Foam Sprinkling System (NFPA 16-2007);

Supply capability

Brand : YINHE

Guarantee period : Within 12 months upon the delivery date

Enquiry Now
Pumping fire truck

1 sku

Pumping fire truck

Technical parameters

1. Emission standard: GIV and GV (optional);
2. Model of chassis: Benz Actros3355;
3. Boundary dimension: 11,000x2,490x3,940mm;
4. Power: 405kW;
5. Max. power supply: 200x2L/s.

Executive standard

GB 7956.1-2014

Supply capability

Brand : YINHE

Guarantee period : Within 12 months upon the delivery date

Enquiry Now
KV082401 Mechanic gloves

1 sku

KV082401 Mechanic gloves

Technical parameters

1. Material: pig skin, super fiber.
2. Color: black.

Executive standard

CE EN388

Supply capability

Brand : KANGSHIELD

Guarantee period : Maintenance method: Store gloves in a dry, light-resistant, room temperature environment. When there is more quantitative material residue, please clean with appropriate solvent, but avoid corrosive cleaning fluid. Gloves should be fully dried after washing, unless instructed by the manufacturer, do not use heat drying gloves, which will cause the gloves to age quickly. Warranty period: 2 years.

Enquiry Now