GT-1000 series point-type gas detector

1 sku

GT-1000 series point-type gas detector

Technical parameters

1. Applicable gases: Combustible gas, toxic gas, oxygen.
2. Test principle: Catalytic combustion type and electrochemical type.
3. Test way: Natural diffusion.
4. Working voltage: DC24V±6V.
5. Power consumption: ≤1.5W.
6. Response time: T90<30s (combustible gas); T90<60s (toxic gas).
7. Operation way: Infrared remote control.
8. Environmental conditions: Temperature: -40℃~70℃ (combustible gas); -20℃~50℃ (toxic gas). Humidity: ≤95%RH no condensation.
9. Status indication: Yellow LED indicates fault, red indicates concentration alarm and green indicates normal working.
10. Applicable cable: ≥RVVP3×1.5mm2, the outside diameter of cable is required as 6mm~9mm.
11. Output signal: 4~20mA, 2-circuit relay output.

Executive standard

GB-15322 1-2003 GB-12358 - 2006

Supply capability

Brand : Hanwei

Guarantee period : 12 months after leaving factory

Enquiry Now
Linear heat fire detector

5 sku

Linear heat fire detector

Technical parameters

1. Operating voltage: DC24V±20%;
2. With constant temperature alarm function, and action temperature has two levels namely 85℃ and 105℃;
3、70℃ ≤ action temperature 85℃<100℃, detector response time is 22s, with deviation.

Executive standard

GB16280-2014 Linear Heat Fire Detector

Supply capability

Brand : Sureland

Guarantee period : 18 months since signing of the contract and 12 months since arrival and acceptance on site, while the priority is given to the first satisfaction of time.

Enquiry Now
Protable single gas detector

1 sku

Protable single gas detector

Technical parameters

1. Detection of gases: oxygen (0-30%).
2. Measurement method: electrochemistry.
3. Sampling method: spread type.
4. Display: digital LCD.
5. Voice alarm: 90 decibels.
6. Visual alarm: red LED.
7. Vibration alarm: vibration.
8. Battery: CR2 battery.
9. The operating temperature and humidity: - 20 ℃ to + 50 ℃, 10% ~ 95% RH.
10. Explosion-proof: EEx ia IIC T4 / IP67;
11. Shell: rubber PC shell.
12. Standard accessories: tape clamp, label cover.
13. Optional accessories: sampling pump.
14. Dimensions: 54mm (W) x91mm (H) x32mm (D)
15. Weight: 120 grams (including battery).

Executive standard

Supply capability

Brand : KANGSHIELD

Guarantee period : Storage instructions: 1. After using the instrument, make sure that the instrument has enough power, or put the amount of power in the underpressure and fill it up. Do not store the instrument when the battery is exhausted, so as not to damage the battery. 2. Keep the equipment in plastic bags or special boxes to keep the environment clean, dry and ventilated, and avoid dust accumulation or dampness. 3. Store the environment 0-40 degrees, away from high temperature and direct sunlight, so as not to damage the instrument or reduce the sensitivity. 4. Should be stored in the environment without corrosive gas, hydrogen sulfide and silicon vapor, avoiding instrument corrosion or poisoning. Instructions: 1. Pay attention to regular calibration and testing. 2. Note the detection interference between various sensors. 3. Pay attention to the life of various sensors. 4. Pay attention to the measuring range of the instrument. Guarantee period: 1 years.

Enquiry Now
Image fire detector

1 sku

Image fire detector

Technical parameters

1. 1920*1080 pixels, min. illuminance is OLux F1.4;0.0002Lux F1.2(DAY), aperture control DC/Video;
2. Fire response time: Flame detection 5-10S, detection delay 10-20S;
3. Sensitivity range: Flame detection is no less than 0.1m², gasoline fire detection range is 150m, and smoke detection is no less than 3% image height;
4. Lens focal length is 12mm, relay output is fire alarm and failure, network output is TCP/IP 10/100M bit/s, power input is DC+12V-+10%/AC220V-+10%, power consumption is 8.0W, and operating temperature is -20-70℃.

Executive standard

GB15631

Supply capability

Brand : Sureland

Guarantee period : 18 months since signing of the contract and 12 months since arrival and acceptance on site, while the priority is given to the first satisfaction of time.

Enquiry Now
GT-WD2200 series spot type gas detector

1 sku

GT-WD2200 series spot type gas detector

Technical parameters

1. Gas to be detected: flammable gas, poisonous gas, oxygen.
2. Detection principle: catalytic combustion type, geochemistry type, semiconductor type, infrared sensor, photoionization type.
3. Detection method: natural proliferation
4. Working voltage: DC24V±6V
5. Detection accuracy: ≤±3%F.S (flammable)
6. Status indication: yellow LED refers to fault; red refers to concentration alarm; green refers to normal working.

Executive standard

GB-15322 1-2003 GB-12358 - 2006

Supply capability

Brand : Hanwei

Guarantee period : 12 moths after delivery

Enquiry Now
OPGD1000 open-circuit detector

1 sku

OPGD1000 open-circuit detector

Technical parameters

1, Testing gas: methane, hydrogen sulfide.
2, Detection principle: laser absorption spectrum.
3, The detection range: 0 ~ 2000ppm · m / 0 ~ 1LEL · m (CH4); 0 ~ 1000ppm · m / 0 ~ 5000ppm · m (H2S).
4, The working distance: 0 ~ 60m; 0 ~ 120m; 0 ~ 220m (optional).
5, Response time: T90 <3s.
6, The environmental conditions: temperature: -40 ℃ ~ 70 ℃; humidity: 0 ~ 95% RH (no condensation).
7, The output signal: 4 ~ 20mA; RS485.

Executive standard

GB-15322 1-2003 GB-12358 - 2006

Supply capability

Brand : Hanwei

Guarantee period : 12 months from the date delivery

Enquiry Now
Portable multi-gas detector

1 sku

Portable multi-gas detector

Technical parameters

Gas detection: oxygen, carbon monoxide, hydrogen sulfide, gas.
Detection range: oxygen 0-30%, carbon monoxide 0-500ppm, hydrogen sulfide 0-100ppm, combustible gas 0-100% LEL.
Sensor type: oxygen - electric couple;Co - electrochemistry;Hydrogen sulphide - electrochemistry.
Combustible gas - catalytic combustion.
Sampling method: spread type.
Display: digital LCD.
Voice alarm: 90 decibels.
Visual alarm: red LED and white backlight.
Vibration alarm: vibration.
Power: alkaline battery, rechargeable NI - MH battery pack.
Operating temperature and humidity: - 20 ℃ ~ + 50 ℃, 15% ~ 90% RH (condensation).
Explosion-proof: Eex ia IIC T4.
Shell: thermoplastic rubber PC shell.
Standard accessories: clip, charger.
Optional accessories: sampling pump.
Size: 54 mm (W) x135mm x36.5 mm (H) (D)
Weight: 240g.

Executive standard

Supply capability

Brand : KANGSHIELD

Guarantee period : Storage instructions: 1. After using the instrument, make sure that the instrument has enough power, or put the amount of power in the underpressure and fill it up. Do not store the instrument when the battery is exhausted, so as not to damage the battery. 2. Keep the equipment in plastic bags or special boxes to keep the environment clean, dry and ventilated, and avoid dust accumulation or dampness. 3. Store the environment 0-40 degrees, away from high temperature and direct sunlight, so as not to damage the instrument or reduce the sensitivity. 4. Should be stored in the environment without corrosive gas, hydrogen sulfide and silicon vapor, avoiding instrument corrosion or poisoning. Instructions: 1. Pay attention to regular calibration and testing. 2. Note the detection interference between various sensors. 3. Pay attention to the life of various sensors. 4. Pay attention to the measuring range of the instrument. Guarantee period: 2 years.

Enquiry Now
Flammable gas detector

1 sku

Flammable gas detector

Technical parameters

Gas detection: LNG, LPG.
Sampling method: built-in sampling pump with flow rate of 0.5 litres/min.
Sensor type: catalytic combustion.
Test range: 0 ~ 100% LEL.
Response time: 5 seconds.
Accuracy: 50 PPM.
Display: digital LCD.
Alarm: buzzer alarm and LCD display.
Gas concentration:
0 ~ 1% LEL - electronic column.
1 ~ 100% LEL - digital display.
Explosion-proof class:
Sensor: Ex d IIC T6.
Detector: Ex ia IIC T4.
Power supply: alkaline battery or rechargeable battery pack.
Operating temperature: - 20 ℃ ~ + 50 ℃.
Duration: more than 12 hours.
Size: 55 mm (W) x241mm x33mm (H) (D)
Weight: 260g.
Options: external probe and charging adapter.

Executive standard

Supply capability

Brand : KANGSHIELD

Guarantee period : Storage instructions: 1. After using the instrument, make sure that the instrument has enough power, or put the amount of power in the underpressure and fill it up. Do not store the instrument when the battery is exhausted, so as not to damage the battery. 2. Keep the equipment in plastic bags or special boxes to keep the environment clean, dry and ventilated, and avoid dust accumulation or dampness. 3. Store the environment 0-40 degrees, away from high temperature and direct sunlight, so as not to damage the instrument or reduce the sensitivity. 4. Should be stored in the environment without corrosive gas, hydrogen sulfide and silicon vapor, avoiding instrument corrosion or poisoning. Instructions: 1. Pay attention to regular calibration and testing. 2. Note the detection interference between various sensors. 3. Pay attention to the life of various sensors. 4. Pay attention to the measuring range of the instrument. Guarantee period: 3 years.

Enquiry Now
HRLD100 hand-held laser telemeter

1 sku

HRLD100 hand-held laser telemeter

Technical parameters

1. Gas to be detected: CH4 (methane). 2. Sensitiveness: 10ppmm. 3. Response time: T90<0.1s. 4. Laser safety grade: detection laser: level I; targeting laser: level IIIa, do not directly glare at laser with eyes or optical instrument. 5. Working voltage: DV3.7V lithium battery; 6600mAh. 6. Working humidity: 0~99%RH (without condensation). 7. Alarming method: sound-light alarm. 8. Display: LCD display. 9. Alarm threshold value: adjustable.

Executive standard

GB-15322 1-2003 GB-12358 - 2006

Supply capability

Brand : Hanwei

Guarantee period : 12 months after delivery

Enquiry Now
Rain-pouring alarm valve

5 sku

Rain-pouring alarm valve

Technical parameters

1. Hydraulic friction resistance: 0.07Mpa;
2. Rated working pressure: 2.5Mpa;
3. Applicable for environment temperature above 0℃;
4. The material is stainless steel.

Executive standard

National standard GB9113.1

Supply capability

Brand : Sureland

Guarantee period : 18 months since signing of the contract and 12 months since arrival and acceptance on site, while the priority is given to the first satisfaction of time.

Enquiry Now