Product characteristics

flow (m³/h)
plunger diameter (mm)
rated pressure
dimension (mm)
chassis model
emission standard
material
weight (kg)
boundary dimension (mm)
boundary dimension(mm)
explosive-proof grade
flow coefficient
plunger stroke (mm)
70
rated flow (l/min)
speed (min-¹)
appearance dimension (mm)
power(kw)
protection grade
specification
water tank volume (m³)
DNCZJ90 Drilling Rig Fire Station

1 sku

DNCZJ90 Drilling Rig Fire Station

Technical parameters

1. Dimension: 14,000 x 2,980 x 3,130 mm;
2. Skid size: 14,000 x 2,980 x 388 mm;
3. Water tank volume: 50 m³;
4. Foam tank volume: 2.8 m³;
5. Motor pump flow: 25 L/s;
6. Motor pump head: 130 m;
7. Diesel pump flow: 25 L/s;
8. Diesel pump head: 109 m.

Executive standard

1. GB7956.1 Fire Engine Part I: General Technical Conditions; 2. GB20031-2005 General Conditions of Foam, Fire Extinguishing Systems, and Components; 3. GB/T 700 Carbon Structural Steel; 4. JB/T 4735 Steel Welding Pressure Vessel; 5. HG/T 20592-20635-2009 Steel Pipe Flanges, Gaskets, and Fasteners; 6. Q/SYBOMCO J075 Steel Structure Welding Code; 7. Q/SYBOMCO J078-2010 General Specification for Paint Painting; 8. NFPA 16-2007 Foam Sprinkler and Foam Sprinkler System Installation Standards.

Supply capability

Brand : YINHE

Guarantee period : 12 months from the date of delivery

Enquiry Now
HRLD100 hand-held laser telemeter

1 sku

HRLD100 hand-held laser telemeter

Technical parameters

1. Gas to be detected: CH4 (methane). 2. Sensitiveness: 10ppmm. 3. Response time: T90<0.1s. 4. Laser safety grade: detection laser: level I; targeting laser: level IIIa, do not directly glare at laser with eyes or optical instrument. 5. Working voltage: DV3.7V lithium battery; 6600mAh. 6. Working humidity: 0~99%RH (without condensation). 7. Alarming method: sound-light alarm. 8. Display: LCD display. 9. Alarm threshold value: adjustable.

Executive standard

GB-15322 1-2003 GB-12358 - 2006

Supply capability

Brand : Hanwei

Guarantee period : 12 months after delivery

Enquiry Now
3GQ4B diesel-driven high-pressure washer (110KW)

14 sku

3GQ4B diesel-driven high-pressure washer (110KW)

Technical parameters

1. Speed (min-¹): 515;
2. Plunger stroke (mm): 70;
4. Rated pressure (Mpa): 10-100;
5. Flow (m³/h): 3.5-30;
6. Plunger diameter (mm): 26-78.

Executive standard

Corporate Standard

Supply capability

Brand : JET

Guarantee period : for 12 months after delivery

Enquiry Now
Rain-pouring alarm valve

5 sku

Rain-pouring alarm valve

Technical parameters

1. Hydraulic friction resistance: 0.07Mpa;
2. Rated working pressure: 2.5Mpa;
3. Applicable for environment temperature above 0℃;
4. The material is stainless steel.

Executive standard

National standard GB9113.1

Supply capability

Brand : Sureland

Guarantee period : 18 months since signing of the contract and 12 months since arrival and acceptance on site, while the priority is given to the first satisfaction of time.

Enquiry Now
Infrared flame detector

3 sku

Infrared flame detector

Technical parameters

1. Detection distance is 42m;
2. Protection angle ≤90°;
3. Operating voltage DC18V-30V (nominal DC24V); 4. Operating current ≤ 35mA (24VDC);
5. Alarm current ≤ 45mA (24VDC);
6. Relay passive point, 0-20mA, bus output;
7. Response time ≤30s;
8. Environment temperature -20℃-60℃;
9. Explosion-proof sign is ExdII CT6 Gb.

Executive standard

GB15631-2008 Special Fire Detector

Supply capability

Brand : Sureland

Guarantee period : 18 months since signing of the contract and 12 months since arrival and acceptance on site, while the priority is given to the first satisfaction of time.

Enquiry Now
Fire control room graphic display device

1 sku

Fire control room graphic display device

Technical parameters

1. Operating voltage: AC220V/50Hz;
2. Communication method: RS232, TCP/IP;
3. Operating temperature: 0℃-40℃;
4. Memory: 2G;
5.CPU:Intel Celeron J1900 1.99GHZ;
6. Hard disk: 32G solid-state disk, extensible;
7. Operating system: Windows7

Executive standard

GB16806-2006 Fire Linkage Control System

Supply capability

Brand : Sureland

Guarantee period : 18 months since signing of the contract and 12 months since arrival and acceptance on site, while the priority is given to the first satisfaction of time.

Enquiry Now
Multi-functional hazardous chemical processing fire truck

1 sku

Multi-functional hazardous chemical processing fire truck

Technical parameters

1. Emission standard: GIV and GV (optional);
2. Chassis model: Germany MAN TGS 33.440/TGS 33.480;
3. Boundary dimension: 10,225x2,500x3,950mm;
4. Power: 327/353kW;
5. Water filling amount: 4,080kg;
6. Neutralization reagent filling amount: 570kg;
7. Fire pump rated pressure: 1.0MPa;
8. Flow of fire pump: 60L/s;
9. Flow of fire monitor: 19-60L/s;
10. Jet range of fire monitor: 70m.

Executive standard

GB 7956.1-2014

Supply capability

Brand : YINHE

Guarantee period : Within 12 months upon the delivery date

Enquiry Now
Pumping fire truck

1 sku

Pumping fire truck

Technical parameters

1. Emission standard: GIV and GV (optional);
2. Model of chassis: Benz Actros3355;
3. Boundary dimension: 11,000x2,490x3,940mm;
4. Power: 405kW;
5. Max. power supply: 200x2L/s.

Executive standard

GB 7956.1-2014

Supply capability

Brand : YINHE

Guarantee period : Within 12 months upon the delivery date

Enquiry Now
Fire Pump Set

1 sku

Fire Pump Set

Technical parameters

1. Dimension: 3,800 x 2,680 x 2,250 mm;
2. Skid size: 3,800 x 2,680 x 388 mm;
3. Water tank volume: 1 m³;
4. Pump flow: 35 L/s;
5. Pump head: 70-120 m.

Executive standard

1. GB7956.1 Fire Engine Part I: General Technical Conditions; 2. GB20031-2005 General Conditions of Foam, Fire Extinguishing Systems, and Components; 3. GB/T 700 Carbon Structural Steel; 4. JB/T 4735 Steel Welding Pressure Vessel; 5. HG/T 20592-20635-2009 Steel Pipe Flanges, Gaskets, and Fasteners; 6. Q/SYBOMCO J075 Steel Structure Welding Code; 7. Q/SYBOMCO J078-2010 General Specification for Paint Painting; 8. NFPA 16-2007 Foam Sprinkler and Foam Sprinkler System Installation Standards.

Supply capability

Brand : YINHE

Guarantee period : 12 months from the date of delivery

Enquiry Now
GT-1000 series point-type gas detector

1 sku

GT-1000 series point-type gas detector

Technical parameters

1. Applicable gases: Combustible gas, toxic gas, oxygen.
2. Test principle: Catalytic combustion type and electrochemical type.
3. Test way: Natural diffusion.
4. Working voltage: DC24V±6V.
5. Power consumption: ≤1.5W.
6. Response time: T90<30s (combustible gas); T90<60s (toxic gas).
7. Operation way: Infrared remote control.
8. Environmental conditions: Temperature: -40℃~70℃ (combustible gas); -20℃~50℃ (toxic gas). Humidity: ≤95%RH no condensation.
9. Status indication: Yellow LED indicates fault, red indicates concentration alarm and green indicates normal working.
10. Applicable cable: ≥RVVP3×1.5mm2, the outside diameter of cable is required as 6mm~9mm.
11. Output signal: 4~20mA, 2-circuit relay output.

Executive standard

GB-15322 1-2003 GB-12358 - 2006

Supply capability

Brand : Hanwei

Guarantee period : 12 months after leaving factory

Enquiry Now