AM Series Microcomputer Protection, Measurement, and Control Device

17 sku

AM Series Microcomputer Protection, Measurement, and Control Device

Technical parameters

See the picture (Note: √ indicates that this function is available; ■ means optional functions; and blank represents no such function.)

Executive standard

Supply capability

Brand : Acrel

Guarantee period : no warranty

Enquiry Now
HSY1 A Amperemeter

3 sku

HSY1 A Amperemeter

Technical parameters

1. Meter frame specification: 2-120mm×120mm (42 square),
3-80mm×80mm (80 square), 9-96mm×96mm (96 square) and D-48mm×48mm (square);
2. Display mode: 1 - single-row digital tube display, 2 - dual-row digital tube display, 3 - three-row digital tube display and Y - liquid crystal display (LCD).
3. The product series: J - basic digital display electric measuring meter, X - digital display electric measuring meter and K - programmable digital measuring meter

Executive standard

GB188021

Supply capability

Brand : HANGSHEN ELECTRIC

Guarantee period : 12 months

Enquiry Now
Polarization Probe

1 sku

Polarization Probe

Technical parameters

1. Probe internal resistance: <200Ω;
2. Service temperature: -20~40℃;
3. Probe material: engineering plastic;
4. Size: φ110×185mm;
5. Test wire length: 5m.

Executive standard

GB/T 21448

Supply capability

Brand : Like

Guarantee period : 12 months

Enquiry Now
Embedded Electric Energy Meter

5 sku

Embedded Electric Energy Meter

Technical parameters

Refer to attached drawings for more information.

Executive standard

GB/T 17215-2002 GB/T 17883-1999

Supply capability

Brand : Acrel

Guarantee period : no warranty

Enquiry Now
Prepaid Electric Energy Meter

4 sku

Prepaid Electric Energy Meter

Technical parameters

Refer to attached drawings for more information.

Executive standard

GB/T 18460.3-2001

Supply capability

Brand : Acrel

Guarantee period : no warranty

Enquiry Now
Miniature digital multimeter

1 sku

Miniature digital multimeter

Technical parameters

/

Executive standard

/

Supply capability

Brand : SHEFFIELD

Guarantee period : /

Enquiry Now
Portable Copper Sulfate Reference Electrode

1 sku

Portable Copper Sulfate Reference Electrode

Technical parameters

1. Electrode impedance: 200Ω~1.6kΩ;
2. Temperature coefficient: 0.9-1.0mv/℃.

Executive standard

GB/T467-1997

Supply capability

Brand : Like

Guarantee period : 12 months

Enquiry Now
ANHPD300 Harmonic Protective Device

1 sku

ANHPD300 Harmonic Protective Device

Technical parameters

1. Rated voltage/rated frequency: AC 400V (three-phase)/50Hz±15%
2. Maximum impulse current value: 12KA
3. Absorption frequency (filter performance): 3KHz~10MHz
4. Leakage current (filter performance): 1.2mA
5. Installation method: three-phase: 35mm (guide rail installation)
6. Installation dimension: 126x105x80 (lengthxdepthxheight)
7. Surge resistance current: for 300V impulse voltage, impulse current shall not exceed 1000A
8. Circuit connection mode: star type
9. Insulation resistance: >100MΩ
10. Withstanding voltage: 2000VAC between current-carrying part and casing for 1min, without breakdown or flashover
11. Power supply: power is less than 1.0w.
temperature rise is less than10℃
12. External interface: terminal
13. Casing type: flame retardant plastic
14. Maintenance mode: maintenance-free
15. Service life: over 15 years
16. Working temperature: -30℃-70℃
17. Storage temperature: -40℃-85℃
18. Relative humidity:﹤85% (Between 15℃ and 25℃)
19. Atmospheric pressure: 52-110Kpa
20. Working environment: without explosive, corrosive gas, conductive dust, violent vibration, impact source and below the altitude of 1500m.

Executive standard

Supply capability

Brand : Acrel

Guarantee period : no warranty

Enquiry Now
Multi-user Metering Box

3 sku

Multi-user Metering Box

Technical parameters

1. Rated Vol.: 3x220/380V.
2. Reference Frequency: 50Hz.
3. Box Power Consumption( as a whole): <20VA.
4. Input Current: Max.3x200A, Max.3x250A.
5. Output Current: 3x5(30) A/3x10(60) A.
6. Startup Current: 0.004lb.
7. Metering Accuracy: Class 1.0.
8. Clock Accuracy: ≤0.5s/d.
9. Pulse Width: 80±20ms.
10. Pulse Constant: Current spec.3x5(30)A/ pulse constant 1600imp/kWh, current spec.3x10(60)A/pulse constant 800imp/kWh.
11. Interface: RS485 (communication line needs shielded twisted pair).
12. Protocol: MODBUS-RTU, DL/T 645-07.
13. Working Temperature: -20℃~+60℃.
14. Storage Temperature: -30℃~+70℃.
15. Moisture: ≤95%RH, places free from dewing and corrosive gases.
16. Altitude: ≤2000m.

Executive standard

Supply capability

Brand : Acrel

Guarantee period : no warranty

Enquiry Now
Digital Display Multimeter

1 sku

Digital Display Multimeter

Technical parameters

Maximum display: 1999-number with automatic polarity display;
Display mode: LCD screen;
Sampling rate: 2-3 times per second;
Operating temperature: 0℃ to +40℃;
Relative power supply: 1.5 V x 3, AAA;
Size: 158 x 75 x 35.

Executive standard

Company standard

Supply capability

Brand : MAXPOWER

Guarantee period : 12 months from the date of delivery

Enquiry Now