0Tkm~9999.9Tkm -30℃~65℃ ExdIIBT4 IP65 MSYF-3 Ton-kilometer Recorder

1 sku

0Tkm~9999.9Tkm -30℃~65℃ ExdIIBT4 IP65 MSYF-3 Ton-kilometer Recorder

Technical parameters

1. Main Hook Tons Kilometer: 0T km to 9999.9T km;
2. Brake Response Time: ≤ 0.1s;
3. Anti-noise Disturbance Ability: 1000Vpp-p, pulse width 1 micro, frequency 30-100Hz;
4. off / on Setting Switch: rotary switch;
5. The Button: instantaneous switch on;
6. Alarm Response Time: ≤ 0.1s;
7. The Power Supply Voltage: DC 24V 50W;
8. The Working Temperature: -30 ℃ ~ 65 ℃;
9. Explosion-proof Grade: ExdIIBT4;10. Protection Class: IP65

Executive standard

Q/JMD16-2016, Q/JMD05-2015"

Supply capability

Brand : MIND

Guarantee period : 12 Months

Enquiry Now
Fixed sleeve flange on-site temperature display

1 sku

Fixed sleeve flange on-site temperature display

Technical parameters

1. Accuracy: ± 1.0% F.S
2. Header accuracy: ± 0.5% F.S, ± 0.2% F.S
3. Stability: better than ± 0.2F.S / year
4. Resolution: 0.1 for <200 and 1 for> 200
5 Start-up time: within 10s after power on
6. Display: 3 and a half LCD
7. Power: Lithium battery section
8. Power consumption: HHG-PC 10 months, 1.5mW level
9. Protection class: better than IP65
10. Installation: no fixed device type,, fixed sleeve threaded type, removable sleeve threaded type,, fixed sleeve flange type,, removable sleeve flange type,

Executive standard

QB

Supply capability

Brand : HENGHE

Guarantee period : 12 months

Enquiry Now
KB2100Ⅱ gas alarm controller

1 sku

KB2100Ⅱ gas alarm controller

Technical parameters

1. Working voltage: AC220±15% 50Hz±1%.
2. Power consumption: ≤5W/ circuit.
3. Matched detector: Detectors with standard 4~20mA output.
4. Environmental conditions: Temperature: -10℃~50℃; Humidity: <95%RH no condensation.
5. Indication way: Concentration data display through LED.
6. Alarm way: Alarm by LED lamp or audible and visual alarm of status.
7. Output signal: Digital quantity: RS485 (standard); Analog quantity: 4~20mA (optional).
8. Contact output: Normally opened for low alarm, normally opened for high alarm, normally opened for fault alarm.
9. Installation way: Wall-mounted type, cabinet type.
10. Requirements for connecting cable of detector and controller: ≥RVVP3×1.5mm2.

Executive standard

GB-15322 1-2003 GB-12358 - 2006

Supply capability

Brand : Hanwei

Guarantee period : 12 months after leaving factory

Enquiry Now
KB9000 gas alarm controller

1 sku

KB9000 gas alarm controller

Technical parameters

1. Power supply: Main power supply: AC 220V±33V 50Hz±5Hz; Emergency power supply: DC 24V±3V rechargeable lead-acid battery.
2. Supply voltage output: DC 24V±6V.
3. Channel of analog detector: 16-channel 4~20mA.
4. Channel of digital detector: 2-channel (RS485), each channel can connect 32 detectors.
5. Digital uploading channel: 1-channel (RS485), supported protocols MODBUS, TC200, Aoruina.
6. Output power of analog detector: Voltage: 27V±3V, protective current of each circuit ≤0.5A.
7. Output power of digital detector: Voltage: 27V±3V, protective current of each circuit ≤2.5A.
8. Total output protective current: ≤5A.
9. Passive relay output: 6 circuits.
10. Relay contact capacity: ≤5A.
11. Operating humidity: ≤95%RH.
12. Display mode: audible (≥85dB), visual alarm.

Executive standard

GB-15322 1-2003 GB-12358 - 2006

Supply capability

Brand : Hanwei

Guarantee period : 12 months after leaving factory

Enquiry Now
Movable sleeve threaded on-site temperature display

1 sku

Movable sleeve threaded on-site temperature display

Technical parameters

1. Accuracy: ± 1.0% F.S
2. Header accuracy: ± 0.5% F.S, ± 0.2% F.S
3. Stability: better than ± 0.2F.S / year
4. Resolution: 0.1 for <200 and 1 for> 200
5 Start-up time: within 10s after power on
6. Display: 3 and a half LCD
7. Power: Lithium battery section
8. Power consumption: HHG-PC 10 months, 1.5mW level
9. Protection class: better than IP65
10. Installation: no fixed device type,, fixed sleeve threaded type, removable sleeve threaded type,, fixed sleeve flange type,, removable sleeve flange type,

Executive standard

QB

Supply capability

Brand : HENGHE

Guarantee period : 12 months

Enquiry Now
4-circuit transmitting output color screen paperless recorder

1 sku

4-circuit transmitting output color screen paperless recorder

Technical parameters

1. Full isolation universal input: HHG-70R series of instruments allows direct input of 40 different types of signals. It has full isolation between channels, and the isolation voltage is greater than 400V;
2. Output signal: Power distribution: 16-circuit power distribution, 8 sets of 24VDC output, output current 60mA / group;
3. Communication Interface: RS-232C, RS-485 and Ethernet RJ45;
4. Transmission output: no requirements, 4-circuit transmitter output, 8--circuit transmitter output, 12--circuit transmitter output

Executive standard

QB

Supply capability

Brand : HENGHE

Guarantee period : 12 months

Enquiry Now
KB2160 gas alarm controller

1 sku

KB2160 gas alarm controller

Technical parameters

1. Working voltage: AC220±15% 50Hz±1%.
2. Power consumption: ≤5W/ circuit.
3. Matched detector: Detectors with standard 4~20mA output.
4. Number of connected detector: 1 set/ circuit.
5. Environmental conditions: Temperature: -10℃~50℃; Humidity: <95%RH no condensation.
6. Indication way: Concentration data display through LED; alarm or fault state display through highlight LED.
7. Alarm way: Audible and visual alarm, gas concentration display through LED.
8. Output signal: Digital quantity: RS485; Analog quantity: 4~20mA; 3-circuit relay output.
9. Installation way: Wall-mounted type, cabinet type.
10. Requirements for connecting cable of detector and controller: ≥RVVP3×1.5mm2.

Executive standard

GB-15322 1-2003 GB-12358 - 2006

Supply capability

Brand : Hanwei

Guarantee period : 12 months after leaving factory

Enquiry Now
Movable sleeve flange type on-site temperature display

1 sku

Movable sleeve flange type on-site temperature display

Technical parameters

1. Accuracy: ± 1.0% F.S
2. Header accuracy: ± 0.5% F.S, ± 0.2% F.S
3. Stability: better than ± 0.2F.S / year
4. Resolution: 0.1 for <200 and 1 for> 200
5 Start-up time: within 10s after power on
6. Display: 3 and a half LCD
7. Power: Lithium battery section
8. Power consumption: HHG-PC 10 months, 1.5mW level
9. Protection class: better than IP65
10. Installation: no fixed device type,, fixed sleeve threaded type, removable sleeve threaded type,, fixed sleeve flange type,, removable sleeve flange type,

Executive standard

QB

Supply capability

Brand : HENGHE

Guarantee period : 12 months

Enquiry Now
Flash alarm without memory function

1 sku

Flash alarm without memory function

Technical parameters

1. Power supply voltage: AC220V ± 10% 50Hz
Or DC 24V ± 10%
2. Ambient temperature: -10 ℃ ~ +45 ℃
3. Relative humidity: ≤ 85%
4. Input method: passive contact, no additional input allowed
Power
5. Relay contact output: AC240V 3A DC28V 5A
6. Loop resistance less than or equal to 30 Ω
7. Power consumption: about 5W (eight loop can be in alarm state at the same time,
excluding bells or buzzer power)
8. Dimensions: 160 × 80 × 80 (mm)
9.Instrument weight: about 0.5Kg
10. Memory function type: without memory function, with memory function

Executive standard

QB

Supply capability

Brand : HENGHE

Guarantee period : 12 months

Enquiry Now
Color screen paperless recorder

1 sku

Color screen paperless recorder

Technical parameters

1. Full isolation universal input: HHG-70R series of instruments allows direct input of 40 different types of signals. It has full isolation between channels, and the isolation voltage is greater than 400V;
2. Output signal: Power distribution: 16-circuit power distribution, 8 sets of 24VDC output, output current 60mA / group;
3. Communication Interface: RS-232C, RS-485 and Ethernet RJ45;
4. Transmission output: no requirements, 4-circuit transmitter output, 8--circuit transmitter output, 12--circuit transmitter output

Executive standard

QB

Supply capability

Brand : HENGHE

Guarantee period : 12 months

Enquiry Now