CI-PC21 infrared gas analyzer

6 sku

CI-PC21 infrared gas analyzer

Technical parameters

1. Measuring principle: NDIR analyzer;
2. Measuring components: one or two components of NOX, SO2, CO, CO2, CH4, H2S are measurable and O2 can be added to each component;
3. Repeatability: ±1% FS;
4. Zero drift: ±1% FS/ 7d;
5. Full scale drift: ±1% FS/ 7d;
6. Linearity error limit: ± % FS;
7. Response time: T90 ≤ 60s (when the sample flow volume is 0.5L/ min);
8. Analog signal: 4-20mA, 0-20mA, 0-1V, 0-5V, 0-10V, 1-5V;
9. Maximum load: to be provided according to user requirements, no impact generated within the maximum load of 500Ω;
10. Environmental conditions: -10 ~ 45°C, not more than 80% RH;
11. Supply voltage: 85-264VAC 50/60Hz

Executive standard

Enterprise standard

Supply capability

Brand : CHANG-AI

Guarantee period : 12 months after goods are received by ERUI

Enquiry Now
Portable Constant Speed Mixer;blender

1 sku

Portable Constant Speed Mixer;blender

Technical parameters

Maximum speed: 18,000 RPM
Low gear speed: 4,000±200 RPM
High gear speed: 12,000±500 RPM
Speed gear: 1,500 ~ 18,000 RPM
Speed display: RPM shown directly
Slurry cup material: stainless steel
Slurry cup volume: 1 L
Input voltage: single-phase AC 220V±10%, 50Hz, 0.8 kW
Ambient temperature: 10 ~ 50°C
Overall dimension: 280×220×300 mm
Instrument weight: 10 kg

Executive standard

Company standard

Supply capability

Brand : SYHK

Guarantee period : 12 months from the date of delivery

Enquiry Now
High Capacity Constant Speed Mixer; agitator

1 sku

High Capacity Constant Speed Mixer; agitator

Technical parameters

Maximum speed: 13,000 RPM
Low gear speed: 4,000±200 RPM
High gear speed: 12,000±500 RPM
Speed gear: 2000 ~ 13,000 RPM
Speed display: RPM shown directly
Slurry cup material: stainless steel
Slurry cup volume: 4 L
Input voltage: single-phase AC 220V±10%, 50Hz, 3 kW
Ambient temperature: 10 ~ 50°C
Overall dimensions: 530×350×900 mm
Weight: 26 kg

Executive standard

Company standard

Supply capability

Brand : SYHK

Guarantee period : 12 months from the date of delivery

Enquiry Now
Recording Atmospheric Consistometer; atmospheric consistometer

1 sku

Recording Atmospheric Consistometer; atmospheric consistometer

Technical parameters

Range of working temperature: room temperature to 93°C
Max. working pressure: atmospheric pressure
Consistency measuring range: 0 ~ 100 Bc
Slurry cup speed: 150±15 RPM
Heater power: 3 kW
Ambient temperature: 10 ~ 50°C
Power supply: single-phase AC 220V±10%, 50Hz
Slurry cup volume: 470 mL
Overall dimensions: 400×450×650 mm
Weight: 34 kg

Executive standard

Company standard

Supply capability

Brand : SYHK

Guarantee period : 12 months from the date of delivery

Enquiry Now
Low-temperature Static Gel Compressive Strength Analyzer; static gel strength

1 sku

Low-temperature Static Gel Compressive Strength Analyzer; static gel strength

Technical parameters

Temperature range: 0 ~ 50°C
Maximum pressure: 138 MPa
Pressure medium: water
Heater power: 2 kW
Refrigerator power: 2.9 kW
Input power supply: refrigerator: single-phase AC 220V±5%, 50Hz, 16A
Instrument: single-phase AC 220V±5%, 50Hz, 5A
Air source pressure: 0.3 ~ 0.7 MPa
Water source pressure: 0.2~0.6 MPa
Ambient temperature: 0 ~ 30°C
Environmental humidity: 0 ~ 70%
Overall dimension: 638×560×994 mm
Instrument weight: 125 kg

Executive standard

Company standard

Supply capability

Brand : SYHK

Guarantee period : 12 months from the date of delivery

Enquiry Now
Variable Temperature and Variable Speed Thickener;pressurization thickener

1 sku

Variable Temperature and Variable Speed Thickener;pressurization thickener

Technical parameters

Working temperature range: 0 to 80℃;
Max. working pressure: 80 MPa;
Max. pressure for low temperature test: 80 MPa;
Max. heating rate: 3℃/min;
Average cooling speed: 1.5℃/min;
Temperature control precision: ±1℃;
Pressure control precision: ±0.7 MPa;
Consistency measuring range: 0-100 Bc;
Consistency resolution: 1 Bc;
Variable speed range: 0.1-600 RPM;
Speed control error: ≤±1%;
Heater power: 4 kW x 2;
Thermal transfer medium pressure: special thickened oil;
Ambient temperature: 10 to 50℃;
Data collection: special software for recorder/thickener;
Execution standard: API standard 10/GB10238-2005;
Three-phase four-wire 380V±10%, 50Hz;
Main engine power: 4.2 X2 kW;
Refrigeration unit power: 4.0 X2 kW;
Variable speed system power: 1 kW;
Air source pressure: 0.3-0.7 MPa;
Water source pressure: 0.2-0.2 MPa

Executive standard

API standard 10/GB10238-2005

Supply capability

Brand : SYHK

Guarantee period : 12 months from the date of delivery

Enquiry Now
Cement Shrinkage Expansion Analyzer; contraction dilatometer

1 sku

Cement Shrinkage Expansion Analyzer; contraction dilatometer

Technical parameters

Max. working temperature: 200°C
Max. working pressure: 69 MPa
Pressure control range: 0 ~ 100% full range (no dead angle control)
Kettle body volume: 200 mL
Max. shrinkage expansion: ±10%
Working voltage: single-phase AC 220V±15%, 50/60Hz
Maximum power: 1 kW
Overall dimensions: 690×530×900 mm
Weight: 60 kg

Executive standard

Company standard

Supply capability

Brand : SYHK

Guarantee period : 12 months from the date of delivery

Enquiry Now
P860 series oxygen/ nitrogen analyzer

6 sku

P860 series oxygen/ nitrogen analyzer

Technical parameters

1. Sensor principle: ion flow oxygen sensor;
2. Measuring accuracy:
10ppm-100ppm O2 ±5%FS;
10ppm-2% O2 ±2%FS;
10ppm-21% O2 ±1.5%FS;
3. Stability: ±2%FS/7d;
4. Response time: T90≤20s;
5. Measurement mode: gas inlet type;
6. Gas flow: 400-600ml/ min;
7. Gas pressure: 86-106kPa;
8. Ambient temperature: 0-45°C;
9. Ambient humidity: <80%RH;
10. Analog output: programmable 4-20mA current output;
11. Relay contact capacity: 24VDC, 0.2A;
12. Power supply: 220VAC ± 10%, 50/ 60Hz or 24VDC.

Executive standard

Enterprise standard

Supply capability

Brand : CHANG-AI

Guarantee period : 12 months after goods are received by ERUI

Enquiry Now
CI-PC95 explosion-proof trance oxygen analyzer

3 sku

CI-PC95 explosion-proof trance oxygen analyzer

Technical parameters

1. Measuring range: 0-10/ 100/ 1000ppm/ 1%/ 25% O2;
2. Sensor principle: fuel cell oxygen sensor;
3. Accuracy:
① 0.01-9.99ppm O2: ±5%FS;
② 10.0-99.9ppm O2: ±3%FS;
③ 100-1000ppm O2: ±2%FS;
4. Repeatability:
① 0.01-9.99ppm O2: ±2.5%FS;
② 10.0-99.9ppm O2: ±1.5%FS;
③ 100-1000ppm O2: ±1%FS;
5. Stability:
① 0.01-9.99ppm O2: ±2.5%FS/7d;
② 10.0-99.9ppm O2: ±1.5%FS/7d;
③ 100-1000ppm O2: ±1%FS/7d;
6. Response time: T90<60s (25°C)
7. Explosion-proof grade: Exd II CT6;
8. IP grade: IP64;
9. Alarm: a group of switching signals, relay contact capacity: 24VDC, 0.2A;
10. Power supply: 24V DC, with analyzer power less than 15VA;
11. Communication: RS485 (standard)/ RS232 (optional);
12. Working environment: -10 ~ 45°C, <90% RH;
13. Sample gas pressure: ordinary pressure ± 10% (pressure at air outlet should be atmospheric pressure).

Executive standard

Enterprise standard

Supply capability

Brand : CHANG-AI

Guarantee period : 12 months after goods are received by ERUI

Enquiry Now
Atmospheric Consistometer; atmospheric consistometer

1 sku

Atmospheric Consistometer; atmospheric consistometer

Technical parameters

Range of working temperature: room temperature to 93°C
Max. working pressure: atmospheric pressure
Consistency measuring range: 0 ~ 100 Bc
Slurry cup speed: 150±15 RPM
Heater power: 3 kW
Ambient temperature: 10 ~ 50°C
Slurry cup volume: 470 mL
Power supply: single-phase AC 220V±10%, 50Hz
Overall dimensions: 400×450×500 mm
Weight: 26 kg

Executive standard

Company standard

Supply capability

Brand : SYHK

Guarantee period : 12 months from the date of delivery

Enquiry Now