Product characteristics

specification (mm2)
size (mm²)
number of cores
specifications (mm²)
rated voltage (uo/ukv)
size (mm² )
nominal section of conductor (mm²)
cross section (mm²)
core number
rated voltage uo/u
specifications (mm2)
rated voltage (v)
section (mm² )
no. of cores
3+1
1
2
3
material grade
rated voltage v
Categories
YJLW02-Z Longitudinally Water Blocking Power Cable with Type-A XLPE Insulation Folded Aluminum Casing and Polyethylene Jacket

15 sku

YJLW02-Z Longitudinally Water Blocking Power Cable with Type-A XLPE Insulation Folded Aluminum Casing and Polyethylene Jacket

Technical parameters

1. Rated power frequency voltage between the conductor-ground or metal shield used for cable design;
2. Long-term maximum allowable temperature at normal operation of the conductor: 90℃;
3.In case of short circuit (the longest duration is not more than 5S), the cable conductor temperature shall not exceed 250℃;
4. The cable's minimum allowable bending radius is generally not less than 25 times of the outer cable diameter.

Executive standard

IEC60840

Supply capability

Brand : QILU

Guarantee period : 12 months from the date of delivery (can be adjusted as needed)

Enquiry Now
YJLW03-Z Longitudinally Water Blocking Power Cable with Type-A XLPE Insulation Folded Aluminum Casing and Polyethylene Jacket

15 sku

YJLW03-Z Longitudinally Water Blocking Power Cable with Type-A XLPE Insulation Folded Aluminum Casing and Polyethylene Jacket

Technical parameters

1. Rated power frequency voltage between the conductor-ground or metal shield used for cable design;
2. Long-term maximum allowable temperature at normal operation of the conductor: 90℃;
3.In case of short circuit (the longest duration is not more than 5S), the cable conductor temperature shall not exceed 250℃;
4. The cable's minimum allowable bending radius is generally not less than 25 times of the outer cable diameter.

Executive standard

IEC60840

Supply capability

Brand : QILU

Guarantee period : 12 months from the date of delivery (can be adjusted as needed)

Enquiry Now
MYPT-1.9/3.3KV Mobile Metal Shielded Rubber Soft Power Cable for Coal Mine

24 sku

MYPT-1.9/3.3KV Mobile Metal Shielded Rubber Soft Power Cable for Coal Mine

Technical parameters

1. Rated voltage Uo/U: 1.9/3.3KV;
2. Allowable long-term cable conductor operating temperature: 90℃;
3. The minimum cable bending radius is 6 times of the cable diameter;
4. The ground wire core of the cable should be well grounded.

Executive standard

MT818

Supply capability

Brand : QILU

Guarantee period : 12 months from the date of delivery (can be adjusted as needed)

Enquiry Now
Type-KYJVP XLPE Insulated PVC Sheathed Copper braid Shielding Control Cable

7 sku

Type-KYJVP XLPE Insulated PVC Sheathed Copper braid Shielding Control Cable

Technical parameters

1. Cable laying temperature: no lower than 0℃;
2. Allowable long-term cable conductor operating temperature: 90℃;
3. Minimum allowable bending radius:
a: The unarmored cable shall be no less than 8 times of the outer cable diameter.
b: The armored cable or that of copper-strip shielding structure shall be no less than 12 times of the outer cable diameter.
C: The flexible cable with a shield structure shall be no less than 6 times of the outer cable diameter.
4. The finished cable can withstand AC 50Hz 3.5KV 5 min pressure test without being penerated through.

Executive standard

GB/T9330

Supply capability

Brand : QILU

Guarantee period : 12 months from the date of delivery (can be adjusted as needed)

Enquiry Now
Type-KYJYP3 XLPE Insulated Polyolefin Sheathed Composite Aluminium-plastics Tape Shielded Control Cable

7 sku

Type-KYJYP3 XLPE Insulated Polyolefin Sheathed Composite Aluminium-plastics Tape Shielded Control Cable

Technical parameters

1. Cable laying temperature: no lower than 0℃;
2. Allowable long-term cable conductor operating temperature: 90℃;
3. Minimum allowable bending radius:
a: The unarmored cable shall be no less than 8 times of the outer cable diameter.
b: The armored cable or that of copper-strip shielding structure shall be no less than 12 times of the outer cable diameter.
C: The flexible cable with a shield structure shall be no less than 6 times of the outer cable diameter.
4. The finished cable can withstand AC 50Hz 3.5KV 5 min pressure test without being penerated through.

Executive standard

GB/T9330

Supply capability

Brand : QILU

Guarantee period : 12 months from the date of delivery (can be adjusted as needed)

Enquiry Now
Type-JKYJ XLPE Insulated Overhead Cable

20 sku

Type-JKYJ XLPE Insulated Overhead Cable

Technical parameters

1. Allowable long-term cable conductor operating temperature: PVC insulated cables should not exceed 70℃; high-density polyethylene insulated cables should not exceed 75℃; and XLPE insulated types should not exceed 90℃;
2. In case of short circuit (the maximum duration is no more than 5S), the maximum temperature of the cable: PVC insulated cables are 160℃; high-density polyethylene insulated cables are 150℃; and cross-linked polyethylene insulated types are 250℃;
3.The cable laying temperature should not be less than -20℃, and below which the cable should be preheated.

Executive standard

GB/T5023

Supply capability

Brand : QILU

Guarantee period : 12 months from the date of delivery (can be adjusted as needed)

Enquiry Now
YJLLW02-Z  Longitudinally Water Blocking Power Cable with Type B XLPE Insulation Folded Aluminum Casing and Polyethylene Jacket

15 sku

YJLLW02-Z Longitudinally Water Blocking Power Cable with Type B XLPE Insulation Folded Aluminum Casing and Polyethylene Jacket

Technical parameters

1. Rated power frequency voltage between the conductor-ground or metal shield used for cable design;
2. Long-term maximum allowable temperature at normal operation of the conductor: 90℃;
3.In case of short circuit (the longest duration is not more than 5S), the cable conductor temperature shall not exceed 250℃;
4. The cable's minimum allowable bending radius is generally not less than 25 times of the outer cable diameter.

Executive standard

IEC60840

Supply capability

Brand : QILU

Guarantee period : 12 months from the date of delivery (can be adjusted as needed)

Enquiry Now
MY-0.38/0.66KV  Mobile rubber cable soft cable for coal mine

100 sku

MY-0.38/0.66KV Mobile rubber cable soft cable for coal mine

Technical parameters

1. Rated voltage Uo/U: 0.38/0.66KV and 0.66/1.14KV;
2. Allowable long-term cable conductor operating temperature: 65℃;
3. The minimum cable bending radius is 6 times of the cable diameter;
4. The ground wire core of the cable should be well grounded.

Executive standard

MT818

Supply capability

Brand : QILU

Guarantee period : 12 months from the date of delivery (can be adjusted as needed)

Enquiry Now
BTLY-0.6/1KV  Mineral-insulated Fireproof Cable

25 sku

BTLY-0.6/1KV Mineral-insulated Fireproof Cable

Technical parameters

1. Specifications (mm2) : 16-400;
2. No. of cores: 3+1.

Executive standard

GB/T5023

Supply capability

Brand : QILU

Guarantee period : 12 months from the date of delivery (can be adjusted according to user requirements)

Enquiry Now
Type A Crosslinked Polyethylene Insulated Fine Wire Armored Polyvinyl Chloride Sheathed Power Cable

6 sku

Type A Crosslinked Polyethylene Insulated Fine Wire Armored Polyvinyl Chloride Sheathed Power Cable

Technical parameters

1. Cable laying temperature ≥0℃;
2. Allowable long-term operating temperature of cable conductor ≤90℃;
3. During short circuit (max. duration no more than 5S), the cable temperature shall not exceed 250℃;
4. Min. allowable bending diameter: single-core cable, 20D (non-armored), 15D (armored). Multi-core cable: non-armored 15D, armored 20D. (Note: D is the measured outer diameter of cable sample in mm).

Executive standard

GB/T12706

Supply capability

Brand : QILU

Guarantee period : 12 months from the date of delivery (can be adjusted according to user requirements)